Categories
Product Overview
Automated manufacturing
Rich wire links
Main Advantage
Internal and external partition, safe and reliable
Stainless material, automatic riveting line
Pay attention to details, see Weizhishu
Automated production, more precise temperature control
Scope Of Application
All kinds of motors, power tools, electronic component transformers, ballasts, glue machines, battery packs, solenoids, electric heating appliances, etc. under 1.5 horsepower.
Technical Characteristics
Model | voltage | 24V DC | 120V AC | 250V AC |
KW***℃ 1T03 | current | 8A | 8A | 6A |
KW***℃ 1B03 | current | 8A | 8A | 6A |
KW-E***℃ 03 | current | 8A | 8A | 6A |
Contact capacity: can operate more than 10,000 times under the following conditions
Dimensions
Model | Metal outer case | ||
L(mm) | W(mm) | H(mm) | |
KW-1T03 | 19.6mm | 7.3mm | 3.6mm |
KW-1B03 | 19.6mm | 7.9mm | 4.2mm |
KW-E 03 | 19.6mm | 7.3mm | 3.6mm |
Number Naming Reference
Safety Certification
UL&CUL: E258861 (UL2111 standard)
CQC: 10002045189 (GB14536.1-2008 standard; GB14536.3-2008 standard) motor thermal protector (iron case)
10002045188 (GB14536.1-2008 standard; GB14536.3-2008 standard) motor thermal protector (plastic case)
ETL&CETL: 3191958 (UL873 standard)
TUV: 50176817
VDE: 40030067 (EN60730-1 standard; EN60730-2-2 standard)
KC: ZU02045-17001 (plastic case K60730-1 standard; iron case K60730-2-2 standard)
CB: CN35137 (IEC60730-2-2 standard)
Patent number: ZL20150124726.6; ZL2015020053967.6
Characteristic Curve
Approximate value is only used to select samples for certification test
These curves are only used to provide guidance when choosing a protector for a specific application. Other factors should be considered when choosing a protector, such as the distance from the heat source and the installation method. The trip time depends on the terminal configuration and installation conditions.
Temperature Specification
Operating Temperature | Reset Temperature | Operating Temperature | Reset Temperature |
40±5℃ | ≥27℃ | 105±5℃ | 70±15℃ |
45±5℃ | ≥30℃ | 110±5℃ | 70±15℃ |
50±5℃ | ≥30℃ | 115±5℃ | 75±15℃ |
55±5℃ | ≥30℃ | 120±5℃ | 80±15℃ |
60±5℃ | ≥35℃ | 125±5℃ | 85±15℃ |
65±5℃ | 40±15℃ | 130±5℃ | 90±15℃ |
70±5℃ | 45±15℃ | 135±5℃ | 95±15℃ |
75±5℃ | 50±15℃ | 140±5℃ | 100±15℃ |
80±5℃ | 55±15℃ | 145±5℃ | 105±15℃ |
85±5℃ | 60±15℃ | 150±5℃ | 110±15℃ |
90±5℃ | 65±15℃ | 155±5℃ | 115±15℃ |
95±5℃ | 65±15℃ | 160±5℃ | 120±15℃ |
100±5℃ | 65±15℃ | Special specifications according to customer requirements |
Operating temperature: 40~160℃±5℃, every 5℃, it is a temperature specification.
Reset temperature: 2/3 of the nominal operating temperature, with a tolerance of ±15°C, or made according to customer requirements.