Your location: Home   Products   Motor Thermal Protector Series  AET200 Series Motor Thermal Protector
AET200 Series Motor Thermal Protector
AET200 Series Motor Thermal Protector

AET200 Series Motor Thermal Protector

Sudden jump bimetal has a high degree of reliability and repeatability
Small size, suitable for applications that are tightly installed on the winding or inside the winding
Additional protective sleeves can be provided according to customer needs
Cost-effective
Product Detail

Product Overview


  • Sudden jump bimetal has a high degree of reliability and repeatability

  • Small size, suitable for applications that are tightly installed on the winding or inside the winding

  • Additional protective sleeves can be provided according to customer needs

  • Cost-effective

The AET200 motor protector can almost meet any protection needs in applications such as small motors, small transformers, and solenoids. This small and compact motor protector can protect various motors in industries and household appliances, and is a solution to protect against locked-rotor and overload conditions.


Applied Range



  • Small motor

  • Coil

  • The electromagnetic valve

  • Transformer

For single-phase motors, the protector can be directly installed on the main circuit as a protector on or in the winding. Its appearance is small and compact, and it is very easy to install even in a small space. AET200 can provide overheating or overload protection for all small motors. Can provide you with low-cost, high-quality and high-reliability solutions.


Design Principle

The AET200 motor protector contains a metal shell, which supports and protects the internal components, while preventing leakage and mechanical deformation. In addition, there is a calibrated metal sheet with silver contacts inside the metal shell. The fixed contact is placed on the other side, separated from the terminal by an insulator.


There are three versions of AET200 to choose from: the type with epoxy resin insulation, the type with insulating yellow paper protective cover, and the type with additional protective cover.


The working principle of AET200 is simple and effective. The current passes through the bimetallic disc with resistance. When a fault occurs, the increased current and ambient temperature cause the bimetallic disc to quickly disconnect from the contact. When the protector temperature drops to a safe operating temperature, the contact is automatically closed.

Dimensions


AET200 motor protector











Technical Characteristics

Contact capacity:

125V AC 3A for TCO

250V AC 3A for TCO
250V AC 1A for TBP
Temperature range:50℃ to 160℃ for TCO/TMP
50°C to 135°C for TBP
Disconnect temperature tolerance: ±3℃, ±5℃, ±7℃, ±10℃, can be customized according to customer needs
Automatic action:Motor is 3C type
Ballast is 2C type
TCO is 2B type
Working hours:continuous work
Pollution status: conventional
Sensing element range:full control
PTI value of insulating material: 250
Protection level:IP00
Electrical connection: on the winding, plug-in type, clamping type, bracket type, glue type, etc.


Temperature Specification

Specifications


  • Break-Off Temperature


Reset Temperature

Specifications

Break-Off Temperature

Reset Temperature

AET200 50℃

50±5℃

35±10℃

AET200 110℃

110±5℃

75±15℃

AET200 55℃

55±5℃

35±12℃

AET200 115℃

115±5℃

75±15℃

AET200 60℃

60±5℃

40±10℃

AET200 120℃

120±5℃

80±15℃

AET200 65℃

65±5℃

45±12℃

AET200 125℃

125±5℃

85±15℃

AET200 70℃

70±5℃

45±15℃

AET200 130℃

130±5℃

90±15℃

AET200 75℃

75±5℃

50±15℃

AET200 135℃

135±5℃

95±15℃

AET200 80℃

80±5℃

55±15℃

AET200 140℃

140±5℃

95±15℃

AET200 85℃

85±5℃

55±15℃

AET200 145℃

145±5℃

100±15℃

AET200 90℃

90±5℃

60±15℃

AET200 150℃

150±5℃

100±15℃

AET200 95℃

95±5℃

65±15℃

AET200 155℃

155±5℃

105±15℃

AET200 100℃

100±5℃

65±15℃

AET200 160℃

160±5℃

105±15℃

AET200 105℃

105±5℃

70±15℃





Operating temperature: 50~160°C±5°C, every 5°C is a temperature specification.

Reset temperature: 2/3 of the nominal operating temperature, with a tolerance of ±15°C, or can be customized according to customer requirements.

Characteristic Curve

The approximation is only used to select samples for certification tests

电机热保护器系列-产品说明书_35_06.png

These curves are only used to provide guidance when choosing a protector for a specific application. Other factors should be considered when choosing a protector, such as the distance from the heat source and the installation method. The trip time depends on the terminal configuration and installation conditions.



Related products
Related cases
Inquiry Now
Name: *
Mobile:
E-mail: *
Message: *
Verification code: *
  
Other products