Product Categories
◆Product parameters
Screw chiller (single head) water cooling series unit technical parameter table (I) | ||||||||
Model/Item | ARC-LG40WSH | ARC-LG50WSH | ARC-LG60WSH | ARC-LG75WSH | ARC-LG85WSH | ARC-LG100WSH | ARC-LG120WSH | |
Cooling capacity | kW | 143 | 187.7 | 201.6 | 269.7 | 317.8 | 373.9 | 437.9 |
Total input power (kW) | 31.1 | 39.0 | 42.9 | 56.1 | 63.7 | 73.9 | 88.3 | |
Operating current upper limit (A) | 70.9 | 88.9 | 97.8 | 127.9 | 145.2 | 168.4 | 201.2 | |
power supply | 3PH-380V-50Hz (220V/415V/460V 50Hz/60Hz) | |||||||
refrigerant | name | R22 (R407c, R134a) | ||||||
Filling volume (kg) | 28 | 35 | 42 | 53 | 60 | 70 | 85 | |
Control method | External balanced temperature sensing thermal expansion valve | |||||||
compressor | type | Semi-enclosed screw type | ||||||
Power (kW) | 31.1 | 39 | 42.9 | 56.1 | 63.7 | 73.9 | 88.3 | |
Startup method | Y-△ | |||||||
Energy adjustment range (%) | 0-33-66-100 | 0-25-50-75-100 | ||||||
Evaporator | type | Dry shell and tube type (stainless steel plate replacement type) | ||||||
Chilled water volume (m³/h)/td> | 24.6 | 32.3 | 34.7 | 46.4 | 54.7 | 64.3 | 75.3 | |
Inlet and outlet pipe diameter | 3" | 3" | 3" | 4" | 4" | 4" | 5" | |
Condenser | type | Shell and tube | ||||||
Cooling water volume (m³/h) | 30 | 39 | 42 | 56 | 66 | 77 | 91 | |
Inlet and outlet pipe diameter | 3" | 3" | 3" | 4" | 4" | 4" | 5" | |
install`Full protection device | Compressor overheat protection, unit overload protection device, high and low pressure protection device, antifreeze protection device, power reverse phase/phase loss protector, fusible plug, water flow switch. | |||||||
Mechanical Dimensions | Length (mm) | 2400 | 2460 | 2513 | 2846 | 2632 | 2945 | 2992 |
Width (mm) | 900 | 900 | 900 | 963 | 963 | 945 | 1035 | |
Height (mm) | 1670 | 1670 | 1727 | 1774 | 1875 | 1870 | 1889 | |
Unit weight | kg | 820 | 950 | 1120 | 1300 | 1560 | 1720 | 2030 |
Operating weight | kg | 970 | 1060 | 1270 | 1480 | 1780 | 1960 | 2250 |
Technical Parameters of Screw Chiller (Single Head) Water Cooling Series Units (II) | |||||||
Model/Item | ARC-LG140WSH | ARC-LG160WSH | ARC-LG180WSH | ARC-LG220WSH | ARC-LG250WSH | ARC-LG280WSH | |
Cooling capacity | kW | 531.8 | 614.7 | 691.3 | 866.5 | 943.1 | 1064.1 |
Total input power (kw) | 106 | 122 | 137 | 168 | 183 | 207 | |
Operating current upper limit (A) | 241.1 | 277.6 | 311.3 | 382.0 | 417.1 | 471.3 | |
power supply | 3PH-380V-50Hz (220V/415V/460V 50Hz/60Hz) | ||||||
refrigerant | name | R22 (R407c, R134a) | |||||
Filling volume (kg) | 98 | 112 | 126 | 154 | 175 | 196 | |
Control method | External balanced temperature sensing thermal expansion valve | ||||||
compressor | type | Semi-enclosed screw type | |||||
Power (kW) | 105.8 | 121.8 | 136.6 | 167.6 | 183.0 | 206.8 | |
Startup method | Y-△ | ||||||
Energy adjustment range (%) | 0-25-50-75-100 | ||||||
Evaporator | type | Dry shell and tube type (stainless steel plate replacement type) | |||||
Chilled water capacity (m³/h) | 91.5 | 105.7 | 118.9 | 149.0 | 162.2 | 183.0 | |
Inlet and outlet pipe diameter | 5" | 5" | 6" | 6" | 6" | 6" | |
Condenser | type | Shell and tube | |||||
Cooling water volume (m³/h) | 110 | 127 | 142 | 178 | 194 | 219 | |
Inlet and outlet pipe diameter | 5" | 5" | 6" | 6" | 6" | 6" | |
install`Full protection device | Compressor overheat protection, unit overload protection device, high and low pressure protection device, antifreeze protection device, power reverse phase/phase loss protector, fusible plug, water flow switch. | ||||||
Mechanical Dimensions | Length (mm) | 3558 | 3558 | 3139 | 3676 | 3676 | 3658 |
Width (mm) | 1097 | 1097 | 1400 | 1450 | 1450 | 1497 | |
Height (mm) | 2009 | 2032 | 1740 | 1816 | 1816 | 2075 | |
Unit weight | kg | 2200 | 2410 | 2630 | 3050 | 3160 | 3350 |
Operating weight | kg | 2430 | 2470 | 2920 | 3270 | 3420 | 3620 |
Remark:
1. The cooling capacity is calculated based on the cooling water inlet temperature of 30°C and outlet temperature of 35°C.
2. Scope of work:
Chilled water temperature range: 5℃ to 30℃; Chilled water inlet and outlet temperature difference: 3℃ to 8℃;
Cooling water temperature range: 18℃ to 30℃; cooling water inlet and outlet temperature difference: 3.5℃ to 10℃.
The working environment temperature should be ≤35℃.
The company reserves the right to change the above parameters or dimensions without prior notice.
Note: The parameters in red font above are for special parameter models. If you have special requirements, please customize them in advance.
◆Characteristics and functions of the unit
1. The compressor adopts imported brand, new high`High efficiency helical rotor compressor.
2. Use high`High-efficiency silicon steel sheets and special slot design, equipped with internal and external omnidirectional cooling channels, make the compressor motor`It can work efficiently under any load.
3. The oil separator adopts double-layer filtering method, which has good oil filtering effect and the heat exchanger can perform its working capacity excellently.
4. High`Efficiency, low noise, low vibration.